FACA-261

Fully Automatic Biochemistry Analyzer

FACA-261
Labomed introduces an automatic biochemistry analyzer with varying testing capacities.

Throughput with 1 Reagent: 250 tests/hour
Throughput with 2 Reagents: 150 tests/hour
With ELE: +150 tests/hour

PDF Brochures
View Brochure by Flipbook
Brochure (English)

Labomed, Inc. is certified by ISO 9001-2013, has CE Conformity and is FDA Licensed.

Features
  • Random access and direct reading system
  • Automatic washing system for both sample and reagent probe
  • Liquid level detection and collision protection for both sample and reagent probe
  • Reliable cooling system for reagent chamber
  • Powerful reaction cuvette washing system
  • User-friendly interface
  • ELE module and barcode scanner (optional)
Accessories
  • 1 Main Machine
  • 50 40-Type Reagent bottles 1
  • 15 Reagent bottle 2 with holder
  • 300 cuvettes
  • 1000 Sample cups
  • 1 Detect Probes
  • 1 Sample Probe
  • 1 Power Cable
  • 1 RS232 Communication Cable
  • 1 Ground cable
  • 1 Sensor
  • 1 Tube
  • 1 Sinkage block
  • 2 Fixed buckle
  • 1 Black Cup
  • 1 Tool
  • 4 Fuse (8A)
  • 1 Lamp (13.8V/50W)
  • 1 User Manual
  • 1 Operation Software CD
  • 1 Certification
Technical Specifications

FACA-261 Specifications

Special Features
  1. Fully Automated Biochemistry Analyzer that can be operated in Random Access, Batch and Stat mode.
  2. Real Time view system, Reagents and sample status.
  3. User defined automatic repeat, dilution and reflex testing.
  4. LIS interfacial.
  5. Long duration of calibration
  6. Sample pre-dilution capability to dilute a sample in the range of 5 to 100 times.
  7. Sample clot and probe crash detection facility
  8. Plastic cuvette
Analytical System Full random access, patient oriented.
Assay types End-point Assay, Rate Assay, Fixed point Assay, Kinetic, Nephelometric.
Test Menu Applications 125
Programmable Tests 120
No. of on-board parameters 60 Photometric Tests + 3 ISE (Na, K, CI)
Throughput 400 Tests / hour, 600-800 Tests with ELE –
you must purchase the FACA-401 with ELE
Test Parameters
Metabolite Glucose HEX, Creatinine, Urea/BUN, Total Bilirubin, Direct Bilirubin, Total
Cholesterol, Triglyceride, HDL Cholesterol, LDL Cholesterol, Albumin, Total
Protein, Iron, UIBC, Calcium, Uric Acid, Urinary CSF Protein, Phosphorous, Bicarbonate, Magnesium, Lactate, Phospholipids, etc.
Enzymes ALP, ALT, AST, CK-MB, CK-NAC, Amylase, ACP, Gamma GT, Lipase, LDH,
Cholinesterase, HBDH, etc.
Nephelometric/ Parameters/Special Proteins HbA1C, C3, C4, IgG, IgM, IgA, Micro albumin, Pre albumin, b2 Micro globulin, APO A1, APO B, ASO, RF, CRP, Ferritin, Myglobin, Transferrin, Ceruloplasmin,
Haptoglobin, a-1 Acid Glycoprotein, a-1 Antitrypsin, etc. 
Therapeutic Drug Monitoring (TDM) Carbamazepine, Digitoxin, Digoxin, Gentamycin, Phenytoin, Phenobarbital,
Theophyline, Valproic Acid, etc.
Drugs of Abuse in Urine (DAU) Amphetamines, Barbiturates, Beta blockers, Benzodiazepines, Cannabinoids, Cocaine, Methadone, Opiates, etc.
Sampler Rack sampler (10 samples per rack; 150 samples can be placed simultaneously).
Stat table (Refrigerated, 22 samples can be placed simultaneously).
STAT samples The STAT sample can be processed prior to the routine sample by using the turntable.
The STAT sample can be processed prior to the routine sample by using the emergency rack.
Repeat run Measurement by STAT table.
Measurement by repeat run rack.
Measurement by automatic repeat run.
Sample  pre dilution Pre-dilutes a sample in the range of 5 to 100 times.
Sample volume 1.6mL in 0.1mL increments (1-25mL for repeats)
Reagent volume R1 : 15 – 250mL; R2: 15 – 250mL; (1 mL increments)
Total reaction volume 120 — 425mL.
Reaction time Up to 8 minutes, 33 Seconds.
Reaction Cuvette Plastic cuvette
Reaction Temperature 37°C.
Incubator Shielded dry bath.
Reagent storages R1: 60 Positions, R2: 48 Positions.
All reagents are refrigerated. Multi-bottle switching.
Wavelength 12-13 wavelengths: 340, 380, 410, 450, 680, 520, 540, 570, 600, 660, 700, 750, 800 nm.
Light source Halogen lamp 12 V/20 W.
Photometric range 0 to 3.0 OD.
Calibration Auto calibration, cooled calibration positions; master calibration established by two-dimensional bar-code of the reagents bottle (>3-point calibration)
Quality Control Auto QC, cooled QC positions.
Test requisition Individual and profile test requisition online, mouse, function keys or touch screen.
Barcode identification Barcode for Rack ID, sample tube ID and reagent ID-
Safety mechanism Sample clot detection and probe crash detection-
Online Full uni-and bi-directional communication possible.
Data storage Up to 100,000 patient samples-
Report, data list Report and data list can be generated in free format-
Data processing Between test calculations, sample blank correction, correlative correction; normal, panic, dynamic and repeat run range judgment; reagent absorbance and reaction mixture absorbance check; abnormal value, pending list repeat run list-
Water Consumption 28 Liters / hour for 800 tests-
Power supply AC 220 VAC ± 10%, 50HZ-
Maximum rated power consumption 3.5 KVA-
Average rated power consumption 3.0 KVA-
Standard Accessories Start up reagents with consumables, controls and calibrators for 3000 tests
(OPTIONAL—MUST BE PURCHASED SEPARATELY)
Warranty 2 Years
Certificate of Quality CE
Testing items:
  • Glucose
  • Blood Urea Nitrogen
  • Creatinine
  • Total Cholesterol
  • Triglycerides
  • Total Bilirubin
  • Total Protein
  • Albumin
  • Globulin
  • Aspartateamino Transferase
  • Alanineamino Transferase
  • Alkaline Phosphatase
  • Chloride
  • Calcium
  • Phosphorous
  • Sodium
  • Potassium
  • Gamma-Glutamyl Transferase
  • High Density Lipoprotein
  • Low Density Lipoprotein
  • Lactate Dehydrogenase
  • Creatine Kinase
  • Magnesium
  • Uric Acid
  • Non Esterified Fatty Acid
  • Amylase

OPTIONAL REAGENTS AVAILABLE UPON REQUEST, INCLUDING:

Diluent 1 Box 20 Liter
Detergent 2 Boxes 5 Liter
Hemolysin 1 Bottle 500 ml